Straightening Bend Copper Tubing of Air Conditioner Filled with Refrigerant
I have a bent copper-tubing of an air conditioner filled with refrigerant that I want to straighten (because I need make some space for mounting a curtain rail). Now, I’m fully aware that it is not recommended to bend/straighten a copper-tubing due to risk of:
Leak
Cooling inefficiency
Since, I really need to mount that rail. I was hoping that someone could see the attached images of the situation, and tell/guide whether
these bends are really severe to cause the risks
If so, what are my options to get this tubing straighten
Will being filled with refrigerant (higher inner pressure) would prevent potential kink?
Red circles: are the bends that I want to straighten.
Green arrow: shows the desired path of the tubing
Box: that the tubing runs into is a large PVC wire channel to get a cleaner look.
Be aware that in the US, at least, releasing the coolant into the atmosphere is illegal. You have to have the system evacuated of coolant to prevent leaks. Something about the ozone and environment and all that. If you attempt to straighten your pipe and crack it open, you’re not only releasing it into the atmosphere, you’re polluting the inside of your dwelling with it. I have no idea how toxic it may be to breathe it for a while as you exit the house then wait for it to clear…
You indicate that you need space for a curtain rail. If you’re hanging an actual curtain from this rail, have you considered mounting the rail above the pipe-set and using the curtain to hide the pipes? If not, maybe mount the rail just below it (for whatever purposes you have in mind), then hang a second one above it with a valence curtain to hide the pipes?
As a final thought, if you do manage to straighten this, you’re going to end up with extra pipe. Where it exits the AC unit, it goes up ~12″ (my guess). You’ll add that 12″ to the length of the pipe, so you’ll have to bend it down the wall 12″ sooner. You’ll then have 24″ extra inches of pipe before it heads into that hole in the corner. What are you going to do with all that extra pipe? It’s not like this is a hose that you can just coil up the spare somewhere…
considered mounting the rail above the pipe-set In the current situation there isn’t much space to mount rail above the pipes. What are you going to do with all that extra pipe? I’ll probably pass it through the wall out side of room.
I’ll probably pass it through the wall out side of room consider that you have a set of stiff copper pipes that you’re working hard to remove bends from (and make at least 2 new 90° bends in), it might be difficult to just “pass it through the wall”. It’s likely, IMHO, that you’ll ruin the pipes in the attempt, but feel free to give this a shot. Just be fully prepared (mentally and financially) to have to do a complete replacement.
First, is that electrical box secured or just hanging on its wires? if it is just hanging that needs to be addressed as well.
Then, is there any spare length in the copper pipe, assuming it is covered by the tape stuff? I think the pipes will be too short if you tried to put two 90 bends in them with a pipe bender. Also, copper pipe work hardens so the original bending will have made the pipe harder to bend a second time around.
I would consider making new pipes to meet the proper run you want then refill the system.
Here is something you can try; get a “C” clamp and put it on the copper at the center of the bend and see if you can smash the copper ever so slightly to remove some of the kink. Do not squeeze the copper too much, just a little to remove some of the kink. This action will not remove the kink but it may make it less severe. If that does not work then do as Solar Mike wrote and redo the copper and refill the system.
Copper Pipe for Transportation System Water
Copper Pipe for Transportation System Water, Copper Pipe Coil For Air Condition, ASTM AC Copper Pancake Tube, Customized Copper Hollow Round Circular Tubing Pipes, AISI ASTM JIS Copper Alloy Structure Piping, refrigerator copper tubing China factory supplier Copper Pipe for Transportation System Water Specification Item Air Condition Or Refrigerator copper tube / copper pipe ,brass […]
Copper Pipe Roil For Air Condition
Copper Pipe Roil For Air Condition, ASTM AC Copper Pancake Tube Copper Pipe, Customized Copper Hollow Round Circular Tubing Pipes, AISI ASTM JIS Copper Alloy Structure Piping, refrigerator copper tubing China factory supplier Copper Pipe Roil For Air Condition Specification Item Air Condition Or Refrigerator copper tube / copper pipe ,brass pipe ,brass tube ,bronze […]
ASTM AC Copper Pancake Tube Copper Pipe
ASTM AC Copper Pancake Tube Copper Pipe, Customized Copper Hollow Round Circular Tubing Pipes, AISI ASTM JIS Copper Alloy Structure Piping Tubing, Construction Works Air Conditioning Pancake Coil Straight Copper Fluid Tubes, refrigerator copper tubing China factory supplier Round Shape ASTM AC Copper Pancake Tube Copper Pipe Specification Product Name Seamless Copper Brass Tube, Seamless […]